MULTILAYER PLUMBING SYSTEM

The RIFENG Plumbing multilayer pipe is a pipe generation that unites the advantages of a plastic and metal pipe and offers a high degree of flexibility and toughness, coupled with high pressure and temperature resistance. The RIFENG Plumbing multilayer pipe consists of a inner and outer layer in between which there is a layer of overlap welded or butt welded aluminum, and the three layers are made to form a permanent structure by means of special bonding layers. The aluminum layer ensure that the pipe maintains its shape and prevent the oxygen penetration from the atmosphere.

Technical specification

Advantages:
• Entirely corrosion-resistant
• A barrier to the permeation of oxygen and light
• High bend flexibility and inherent stability
• Excellent hydrostatic stress performance
• Light in weight
• Smooth inner wall ensures less pressure loss
• Service life up to 50 years


Applications:
RIFENG Multlayer plumbing system can be used in following applications:
Hot and cold water distribution.
Standards:
EN ISO 21003 - Multilayer piping systems for hot and cold water installations inside buildings
ASTM F1281 - Standard Specification For Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure Pipe.
BRL-K536 E - Plastics piping systems of PE-X/Al intended for the transport of cold and heated drinking water 
DVGW W 534 (P) - Pipe Connectors and Pipe Joints in Drinking Water Installation
DVGW W 542 - COMPOUND PIPES IN THE DRINKING WATER INSTALLATION; REQUIREMENTS AND TESTING
DVGW W 270 - A method for the assessment of enhancement of microbial growth on non-metallic materials in contact with drinking water
UBA KTW - about Hygienic property of material odor test
UBA ELASTOM - Guideline for hygienic assessment of elastomers in contact with drinking water
AS 4176.2 & 3 - Multilayer piping for pressure applications - Multilayer piping systems for hot and cold water plumbing applications- PIPES & FITTINGS
XP P41-250 - Effect of materials on the quality of water intended for human consumption - Organic materials
NSF /ANSI /CAN 61 - Health Effects of Drinking water system components


Certificates:
AENOR - refers to EN ISO 21003
NF - refers to ISO EN ISO 21003
QB - refers to EN ISO 21003
KIWA - refers to BRL-K536 E
DVGW - refers to DVGW W 534 (P), DVGW W 542, DVGW W 270, UBA KTW, UBA ELASTOM
ACS - refers to XP P41-250
WaterMark - refers to AS 4176.2 & 3
NSF - refers to ASTM F1281 and NSF /ANSI /CAN 61
WRAS - refers to Regulators’Specification
STF - refers to EN ISO 21003
ISO 9001:2015 – “Quality management system”


          

TYPE Multilayer Pipe      
Overlapped welded A(PE-AL-PE) B1 (PEX-AL-PEX) B (PERT-AL-PERT) C (PE-AL-PE)
Roughness(mm) 0.0007 0.0007 0.0007 0.0007
Melting point (℃) 135 127 127
Density (g/cm3) 0.941-0.959 0.926-0.959 0.926-0.940 0.941-0.959
Modulus of elasticity
(MPa)
7200 7200 7200 7200
Thermal conductivity 
(w/mK)
0.45 0.45 0.45 0.45
Coefficient of thermal expansion (mm/mK) 0.025 0.025 0.025 0.025
 
Material Test item Requirement
Polyethylene Density HDPE0.941~0.959 g/cm3 MDPE0.926~0.941 g/cm3
(PEX) Melt flow index HDPEMDPE≥0.1 g/10min(1902.16kg)
Tensile strength HDPE≥21MPaMDPE≥14MPa
Enlongation ≥400%
Vicat soft point Vicat soft point≥105℃
Cross-linking degree ≥65%
ESCR ≥165h
Color masterbatch Moisture content ≤0.15%
Appearance Uniform granual
Volatile content ≤0.5%
catalyst Density ≥0.93 g/cm3
Melt flow index ≥0.9 g/10min190℃5.00kg
Volatile content ≤0.35%
Adhesive resin Appearance Uniform granual
Density ≥0.926 g/cm3
Melt flow index 2.0~6.0 g/10min190℃2.16kg
Vicat soft point Vicat soft point≥105℃
T peeling strength ≥70N/25mm
Aluminum Surface quality Water brush test≥class
Tensile strength 105MPa125MPa
Appearance Without oil on surface
Hardness(HV) 2833
T peeling strength Minimum value≥60N/25mm
Nominal size(D x e) 14×2.0 16×2.0 18×2.0 20×2.0 25×2.5 32×3.0 40x4.0 50x4.5 63x6.0 75x7.5
Outside diameter (mm) 14 16 18 20 25 32 40 50 63 75
Tolerance of Outer diameter  (mm) Min 14.00 16.00 18.00 20.00 25.00 32.00 40.00 50.00 60.60 70.70
Max 14.20 16.20 18.20 20.20 25.20 32.20 40.40 50.50 63.00 75.00
Inside diameter(mm) 10 12 14 16 20 26 32 41 51 60
Tolerance of Inner diameter (mm) Min 9.90 11.90 13.90 15.90 19.90 25.90 30.90 39.40 49.30 57.70
Max 10.20 12.20 14.20 16.20 20.20 26.20 31.90 40.80 50.80 59.70
Pipe thickness (mm) 2 2 2 2 2.5 3 4 4.5 6 7.5
Tolerance of pipe thickness (mm) Min 2.00 2.00 2.00 2.00 2.40 2.90 4.00 4.50 6.00 7.50
Max 2.25 2.25 2.25 2.25 2.70 3.20 4.60 5.20 6.80 8.50
Compression connections:
This fittings allows for the connection of multilayer pipe. On the coupling ends, the union with the polyethylene inner tube is sealed by O-rings placed on the removable insert that is introduced into the fitting body and into the tube. The connection is tightened by the nut with wrench

Press connections:
Use special tools, phisically press a connection onto the pipe to make an impermeable connection or seal. RIFENG provide 4 different press fittings.
F5 used with U profile crimper
F9 (leakage indicate) used with TH profile crimper 
F17 used with U, TH, H, RFZ profile crimper
F18 (leakage indicate) used with U, TH, H, RFZ profile crimper